Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Antonie Van Leeuwenhoek ; 117(1): 46, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38427093

RESUMEN

The fast-growing rhizobia-like strains S101T and S153, isolated from root nodules of soybean (Glycine max) in Sichuan, People's Republic of China, underwent characterization using a polyphasic taxonomy approach. The strains exhibited growth at 20-40 °C (optimum, 28 °C), pH 4.0-10.0 (optimum, pH 7.0) and up to 2.0% (w/v) NaCl (optimum, 0.01%) on Yeast Mannitol Agar plates. The 16S rRNA gene of strain S101T showed 98.4% sequence similarity to the closest type strain, Ciceribacter daejeonense L61T. Major cellular fatty acids in strain S101T included summed feature 8 (C18:1ω7c and/or C18:1ω6c) and C19:0 cyclo ω8c. The predominant quinone was ubiquinone-10. The polar lipids of strain S101T included diphosphatidylglycerol, phosphatidylglycerol, phosphatidylmethyl ethanolamine, phosphatidyl ethanolamine, amino phospholipid, unidentified phosphoglycolipid and unidentified amino-containing lipids. The DNA G + C contents of S101T and S153 were 61.1 and 61.3 mol%, respectively. Digital DNA-DNA hybridization relatedness and average nucleotide identity values between S101T and C. daejeonense L61T were 46.2% and 91.4-92.2%, respectively. In addition, strain S101T promoted the growth of soybean and carried nitrogen fixation genes in its genome, hinting at potential applications in sustainable agriculture. We propose that strains S101T and S153 represent a novel species, named Ciceribacter sichuanensis sp. nov., with strain S101T as the type strain (= CGMCC 1.61309 T = JCM 35649 T).


Asunto(s)
Soja , Fosfolípidos , Humanos , ARN Ribosómico 16S/genética , Análisis de Secuencia de ADN , Filogenia , ADN Bacteriano/genética , Fosfolípidos/química , Ácidos Grasos/química , Etanolaminas , China , Técnicas de Tipificación Bacteriana
2.
Accid Anal Prev ; 196: 107445, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38159512

RESUMEN

The extraction and analysis of driving style are essential for a comprehensive understanding of human driving behaviours. Most existing studies rely on subjective questionnaires and specific experiments, posing challenges in accurately capturing authentic characteristics of group drivers in naturalistic driving scenarios. As scenario-oriented naturalistic driving data collected by advanced sensors becomes increasingly available, the application of data-driven methods allows for a exhaustive analysis of driving styles across multiple drivers. Following a theoretical differentiation of driving ability, driving performance, and driving style with essential clarifications, this paper proposes a quantitative determination method grounded in large-scale naturalistic driving data. Initially, this paper defines and derives driving ability and driving performance through trajectory optimisation modelling considering various cost indicators. Subsequently, this paper proposes an objective driving style extraction method grounded in the Gaussian mixture model. In the experimental phase, this study employs the proposed framework to extract both driving abilities and performances from the Waymo motion dataset, subsequently determining driving styles. This determination is accomplished through the establishment of quantifiable statistical distributions designed to mirror data characteristics. Furthermore, the paper investigates the distinctions between driving styles in different scenarios, utilising the Jensen-Shannon divergence and the Wilcoxon rank-sum test. The empirical findings substantiate correlations between driving styles and specific scenarios, encompassing both congestion and non-congestion as well as intersection and non-intersection scenarios.


Asunto(s)
Accidentes de Tránsito , Conducción de Automóvil , Humanos , Accidentes de Tránsito/prevención & control , Encuestas y Cuestionarios , Movimiento (Física)
3.
J Orthop Surg Res ; 14(1): 152, 2019 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-31126302

RESUMEN

RATIONALE AND OBJECTIVES: The aim of this study was to investigate the efficacy of magnetic resonance imaging (MRI) with a spoiled gradient-recalled (SPGR) sequence to evaluate early knee cartilage degeneration and the relationship between cartilage and other tissues using a modified Whole-Organ Magnetic Resonance Imaging Score (WORMS). MATERIALS AND METHODS: Eighty-four patients with knee joint pain were evaluated by X-ray and MRI with an SPGR sequence from June 2015 to December 2016. Joint degeneration was graded by two experienced radiologists using the Kellgren-Lawrence (K-L) grading scale. The modified WORMS was used to evaluate cartilage lesions, bone marrow abnormalities, bone cysts, osteophytes, joint effusion and synovitis. The difference between the WORMS of the SPGR and the T2 sequences evaluated by the Wilcoxon signed-rank test was determined, and the relationships between the WORMS features were evaluated by a Spearman correlation. RESULTS: The modified WORMS for the cartilage lesion evaluation was significantly higher with the SPGR sequence than with the T2 sequence (P < 0.05). The cartilage lesions showed a moderate correlation with osteophytes, synovitis and joint effusion (Rs > 0.40, P < 0.05) and weak correlations with bone marrow abnormalities and bone cysts (Rs < 0.4, P < 0.05). CONCLUSION: The modified WORMS evaluation using MRI with the SPGR sequence was much better than the normal sequence for early knee osteoarthritis (OA). The cartilage lesions are associated with bone marrow abnormalities and the other features of OA.


Asunto(s)
Artralgia/diagnóstico por imagen , Cartílago Articular/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/normas , Adolescente , Adulto , Anciano , Diagnóstico Precoz , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
4.
Chin Med J (Engl) ; 128(18): 2516-23, 2015 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-26365972

RESUMEN

BACKGROUND: Researchers initially proposed the substitution of apoptotic chondrocytes in the superficial cartilage by injecting mesenchymal stem cells (MSCs) intraarticularly. This effect was termed as bio-resurfacing. Little evidence supporting the treatment of osteoarthritis (OA) by the delivery of a MSC suspension exists. The aim of this study was to investigate the effects of injecting allogenic MSCs intraarticularly in a rat OA model and to evaluate the influence of immobility on the effects of this treatment. METHODS: We established a rat knee OA model after 4 and 6 weeks and cultured primary bone marrow MSCs. A MSC suspension was injected into the articular space once per week for 3 weeks. A subgroup of knee joints was immobilized for 3 days after each injection, while the remaining joints were nonimmobilized. We used toluidine blue staining, Mankin scores, and TdT-mediated dUTP-biotin nick end labeling staining to evaluate the therapeutic effect of the injections. Comparisons between the therapy side and the control side of the knee joint were made using paired t-test, and comparisons between the immobilized and nonimmobilized subgroups were made using the unpaired t-test. A P value < 0.05 was considered significant. RESULTS: The three investigative approaches revealed less degeneration on the therapy sides of the knee joints than the control sides in both the 4- and 6-week groups (P < 0.05), regardless of immobilization. No significant differences were observed between the immobilized and nonimmobilized subgroups (P > 0.05). CONCLUSIONS: Therapy involving the intraarticular injection of allogenic MSCs promoted cartilage repair in a rat arthritis model, and 3-day immobility after injection had little effect on this therapy.


Asunto(s)
Cartílago Articular/citología , Trasplante de Células Madre Mesenquimatosas/métodos , Células Madre Mesenquimatosas/citología , Osteoartritis de la Rodilla/prevención & control , Osteoartritis de la Rodilla/terapia , Animales , Inyecciones Intraarticulares , Masculino , Ratas
5.
Beijing Da Xue Xue Bao Yi Xue Ban ; 44(6): 882-6, 2012 Dec 18.
Artículo en Chino | MEDLINE | ID: mdl-23247451

RESUMEN

OBJECTIVE: To observe the incidence of skin sensory loss after total knee arthroplasty (TKA) and its natural history over time, and to identify the relationship between numbness area and incision length, tourniquet time, age and gender. METHODS: In the study, 132 patients (20 males and 112 females, with an average age of 69.75 years old, 135 cases of TKA) who underwent primary TKA with midline incisions were chosen and grouped chronologically (4 years, 3 years, 2 years, 1 year, 6 months, 1 month) to the investigation time point from Peking University First Hospital. All the operations were done by the same surgeon team with Stryker NRG and Depuy RP (without patellar resurfacing). Numbness incidence, numbness area, scar length, tourniquet time were recorded from the questionnaires sent to the patients and their medical records. RESULTS: 84.44% of the patients received a reduced skin sensory after TKA, 91.22% of which had a smaller numbness area gradually over time. The numbness area was decreased from the 1 month postoperation group to the 4 years postoperation group (P <0.001). The numbness area in 2 years postoperation group and more were significantly smaller than 1 month postoperation group (P=0.042, 0.004, 0.022), however, the skin flap numbness area had little change after 2 years (P>0.05). The hypoesthesia flap was completely lateral to the incision in 88.60% of the patients, and the numbness area covered the lateral skin and part of media skin to the incision in 11.40% of the patients. Numbness size had no relationship with the patients' gender, age, length of scar and tourniquet time (P>0.05). CONCLUSION: Most but not all the patients have a dermal hypoesthesia after total knee arthroplasty. The numbness area will gradually reduce over time. Numbness size is obviously smaller 2 years postoperation and then it will be stable. Gender, age, length of incision, and tourniquet time have no significant relationship with the size of numbness.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Hipoestesia/etiología , Anciano , China/epidemiología , Femenino , Humanos , Hipoestesia/epidemiología , Incidencia , Masculino , Persona de Mediana Edad , Osteoartritis/cirugía , Estudios Retrospectivos , Piel/inervación
6.
Zhonghua Wai Ke Za Zhi ; 48(8): 601-5, 2010 Apr 15.
Artículo en Chino | MEDLINE | ID: mdl-20646478

RESUMEN

OBJECTIVE: To evaluate the effects of cementless revising cup or acetabular reinforcement cages for reconstructing the massive acetabular deficiency. METHODS: From September 2001 to September 2008, 22 loosening acetabular cases (24 hips) were revised using cementless revising cup or acetabular reinforcement cases for reconstructing massive bone defect after particulate bone grafting. There were 2 cases (2 hips) using Lima cementless revising cup, 2 cases (2 hips) using Kerboull ring, and 18 cases (20 hips) using restoration GAP cages. Six cases (6 hips) were male, and 16 cases (18 hips) were female. The mean age was 62 years old (34 - 79 years old). Septic loosening was in 2 cases (2 hips), and aseptic loosening in 20 cases (22 hips). The mean follow-up was 48 months (18 - 84 months). RESULTS: There was no clinical or radiological evidence of loosening for the revising acetabular components at the last follow-up point. The mean Harris hip score was improved significantly from 56 points (44 - 75) before revision to 89 points (78 - 94) at the last follow-up after revision. Excellent and good rate was 95.5% (21/22 cases). The average abduction angle of the three types of acetabular reconstructive cages were 50.1 degrees (39.0 degrees - 66.0 degrees), and almost all cases of the hip rotation center were restored after revision surgery. At the last follow-up, the reinforcement cages were no immigration and breakup, and there was no radiolucent line around the acetabular components. The bone graft integrated well into surrounding acetabular bone. CONCLUSION: The method of revising the massive acetabular bone defect by cementless revising cup and acetabular reinforcement cages restores the normal hip rotation center, supplies the primary stability of the revising component, and protects the bone graft from mechanical overload during its revascularization phase, which is a reliable method for revising the massive acetabular deficiency after total hip arthroplasty.


Asunto(s)
Acetábulo/cirugía , Prótesis de Cadera , Adulto , Anciano , Artroplastia de Reemplazo de Cadera , Trasplante Óseo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/métodos , Stents
7.
Zhonghua Wai Ke Za Zhi ; 47(24): 1888-91, 2009 Dec 15.
Artículo en Chino | MEDLINE | ID: mdl-20193409

RESUMEN

OBJECTIVES: To measure the linear polyethylene wear with use of a computer-assisted two-dimensional method, and to evaluate the relationship between wear and long-term clinic-radiological findings. METHODS: Between December 1991 and December 1995, the senior author performed 40 primary total hip arthroplasties with use of H/G porous-coated acetabular component. Radiographs of 40 H/G cementless total hip arthroplasties were examined for osteolysis, radiolucent line, cup migration and so on. To measure the linear polyethylene wear, migration in the femoral head center relative to the cup shell center was calculated on digitized consecutive radiographs with special computer software program. RESULTS: The minimum follow-up was 10 years. Total linear wear was 2-8 mm, the mean rate of linear polyethylene wear was (0.32+/-0.31) mm/year. Twelve acetabular components (30%) were revised at an average follow-up point of 12 years. Three types of polyethylene liner failure were identified: wear-through of the polyethylene liner with resultant metallosis (5 hips), excessive wear necessitating revision (5 hips), and polyethylene liner dissociation without gross evidence of wear (2 hips). CONCLUSIONS: High wear rates and femoral and acetabular osteolysis have been and still are the main problems in uncemented total hip replacement. There is clear relationship between wear and acetabular osteolysis or loosening of the prostheses. The poor long-term results with these uncemented total hip arthroplasties illustrate the necessity of regular radiographic evaluation in order to detect osteolysis and liner failure, which are both generally asymptomatic until catastrophic failure appears.


Asunto(s)
Prótesis de Cadera , Complicaciones Posoperatorias , Falla de Prótesis , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Osteólisis/etiología , Polietileno , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...